The new AutoSense meter is designed for easy, accurate, and quick testing of blood glucose level.

 

It does not require manual coding, which makes testing easier and faster and eliminates errors associated with miscoded meters. AutoSense also offers hygienic operation and the broadest, most user-friendly features available in a blood glucose meter.

 

The talking function of AutoSense Voice makes this meter very easy to use, even for those who are visually impaired. Clear and simple sentences spoken in a human voice lead users through the testing steps and allow them to hear the test results.

Features & functions

 

  • Auto-coding Biosensor Technology
  • Ergonomic and compact design 
  • Easy and hygienic operation 
  • Excellent accuracy and quick results (average 5 sec) 
  • Small blood sample (0.5 µl) and AST function for less pain 
  • Large memory capacity (last 500 test data) with averaging function 
  • Optional whole blood calibration or plasma equivalent calibration 
  • Optional talking function in AutoSense Voice
  • Broad range of user-friendly features
  • ISO 15197:2013 compatibility

 

Auto-coding system

The AutoSense meter has an autocoding system to ensure that the meter and the strips work together properly. Thus, manual coding of the meter is not necessary. The insertion of the test strip will automatically switch the meter on.

 

Small sample volume

Only a tiny drop of blood (0.5 μl) is needed for an accurate measurement, which makes testing virtually pain-free.

 

Rapid test results

The results can be read on the large LCD display in just 5 seconds.

 

Two measurement units, optional calibration

The AutoSense meter can display the results using 2 different units of measurement: mmol/l or mg/dl. One mmol/l is equivalent to approximately 18 mg/dl. The calibration of the meter is also optional: Both whole blood and plasma equivalent calibrations are available.

 

Large memory capacity, average calculation

AutoSense is capable of storing the last 500 test results (including dates and times), and it can also calculate 7-, 14-, 30-, 60-, and 90-day average values. The calculated average includes all the test results from the selected period, except for those that have been marked.

 

Strip ejection

To avoid blood contact, used strips can be discarded easily using the strip ejector button. This makes strip handling much simpler and more hygienic.

 

Special flags

Premeal, postmeal, and sport activity flags can be set for each measurement result to make the measurement process more precise. Additionally, false or control measurement results can be marked such that they are not used for calculating average glucose levels.

 

Data download

Using the LiteLink mini USB device, the stored data can be downloaded to a PC via the infrared (IR) interface of the meter. Downloaded data can be tracked using the Diatransfer 2 diabetes management software.

 

Alternate site testing

The alternate site blood sampling function can be used when blood samples are collected from sites other than the fingertips (palms, forearms, and upper arms) to ensure less pain during collection.

 

Alarm function

Three daily alarms can be set by the user to serve as testing reminders.

 

Talking function

This feature is available in AutoSense Voice. When the talking function of AutoSense Voice is enabled, important instructions and values displayed on the screen are vocalized. This is a great help for people who may have problems reading the characters displayed on the screen. Thus, the potential for misuse or misreading due to poor sight can be reduced significantly.

 

 

Package contents

 

  • AutoSense Blood Glucose Meter with battery
  • Adjustable lancing device with disposable lancets
  • Check-strip
  • Instructions for use
  • Quick Reference Guide
  • Carrying case

 

 

Type: advanced auto-coding biosensor technology
Sample: min. 0.5 µl capillary whole blood
Operating range: temperature: 10 - 40 °C
relative humidity: <90%
altitude: below 3000 m
hematocrit: 30-55%
Measuring range: 20 – 600 mg/dl (1.1-33.3 mmol/l)
Average test time: 5 seconds
Memory capacity: last 500 test data with time and date
Talking function: in AutoSense Voice
Automatic switch on: upon insertion of test strip
Automatic power off: in 2 minutes after the last button activation
Warning and error signals: out of measuring range (Low / High), 
hypoglycemia, insufficient sample detection,
low / high temperature, low battery
Alarm function: daily 3 alarms
Batteries: 1 pc. 3V, type: CR2032 /
(2 pcs. 3V, type: CR2032)
Battery life: 1 year or 1500 measurements /
(1 year or 1000 measurements)
Display: LCD
Interfaces: Infrared port to LiteLink Data Download Device
Dimensions: 55x100x21 mm
Weight: 60 g / (90 g)
  • AutoSense & AutoSense Voice_Brochure

    Download
  • Product description
  • Specification
  • Downloads
product details pattern
  • For distributors

    In case of technical inquiries please visit the For Distributors menu.

    Log in

  • Follow us

    Like and follow us on our social media channels for extra contents.

footer pattern